Tag: Military bases
Clear
  • Analysis of the Army Transition from LEED 2009 to LEED v4, with Updated LEED 4.1 Credits

    Abstract: The objective of this effort was to identify and recommend an approach for Army green building certification that ensures Army projects meet federal and Army sustainability requirements during the transition from Leadership in Energy and Environmental Design (LEED) 2009 to LEED v4. The first Army LEED v4 project was registered for certification with the Green Building Certification Institute in 2014. Since then, over 860 Army projects were registered for LEED v4 certification. As of the third quarter of FY20, when this report was written, 2 projects achieved LEED Silver certification. Other Army projects teams documented difficulty achieving the required LEED v4 Silver certification due to difficult site conditions, budget constraints, facility types, or project requirements. Commercial-sector project teams also had difficulty certifying with LEED v4, forcing the United States Green Building Council (USGBC) to reconsider the credits and metrics project teams found challenging. The USGBC revised the troublesome credits and now offers LEED v4.1 pilot credits that can be used for any project registered with LEED v4. To assist Army project teams, this research investigates difficult-to-achieve LEED v4 cred-its and their possible replacement with LEED v4.1 pilot credits. The report concludes with guidance on implementing the updated version of the LEED rating system from v4 to v4.1.
  • Evaluation of a Visible Light Responsive Photocatalytic Coating to Resist Microbial Contamination and Increase Indoor Air Quality

    Abstract: To meet new Department of Defense (DoD) energy standards, buildings are being constructed, and existing buildings are being retrofitted with tighter envelops. These new standards can reduce operational costs significantly but also limit fresh outdoor air coming into the built environments. This can result in the accumulation of harmful substances within buildings, which can have adverse effects on its occupants. New photocatalytic coatings may be a solution to this ever-increasing problem as they have the ability to destroy both chemical and biological toxins when activated with light. This work evaluated a novel indoor-light-reactive photocatalytic coating for its ability to eliminate or reduce microbial contamination under in situ test conditions. However, air and surface sampling revealed no reduction in either viable fungi and bacteria or total air-borne mold spores. Additionally, no significant differentiation could be made in the composition of volatile organics between the treated and untreated areas. However, testing the photocatalytic activity of the coating with standardized test methods and increased illumination, revealed the coating did exhibit antimicrobial activity against mold, bacteria, and viruses. This suggested that there may be limited benefit to using the indoor-light-reactive photocatalytic coating to inhibit microbial contamination unless specific lighting conditions can be met.
  • Stormwater Management Practices, Monitoring, and Maintenance Plan for US Army Garrison at West Point, NY

    Abstract: Structural stormwater management practices (SMPs) are designed and installed with the goal of reducing runoff and improving water quality through a variety of built (e.g., underground chamber and filter systems), nature-based and natural features (e.g., rain gardens, swales). In compliance with Section 402 of the US Clean Water Act (CWA), US Army Garrisons at West Point MS4 operators are required to obtain a National Pollutant Discharge Elimination System permit or a New York State Pollutant Discharge Elimination System (SPDES). These permits require development of stormwater management plans to reduce pollutants to meet the appropriate water quality standards. Over 62 structural SMPs have been installed at the US Army Garrison (USAG) to meet permit requirements. Monitoring and maintenance are essential to maintain and understand the effectiveness of these structures, track their maintenance needs, and improve their function. This document provides guidance for conducting stormwater management practice, inspection, and maintenance at the United States Army Garrison at West Point. The objectives are to inform installation managers on general SMP functions and designs, highlight key maintenance triggers affecting SMP functionality, and provide guidance on when and how to conduct inspections and maintenance actions specific to USAG SMPs and in accordance to NYS DEC.
  • Naval Expeditionary Runway Construction Criteria: P-8 Poseidon Pavement Requirements

    Abstract: A full-scale airfield pavement test section was constructed and trafficked by the US Army Engineer Research and Development Center to determine minimum rigid and flexible pavement thickness requirements to support contingency operations of the P-8 Poseidon aircraft. Additionally, airfield damage repair solutions were tested to evaluate the compatibility of those solutions with the P-8 Poseidon. The test items consisted of various material thickness and strengths to yield a range of operations to failure allowing development of performance predictions at a relatively lower number of design operations than are considered in traditional sustainment pavement design scenarios. Test items were trafficked with a dual-wheel P-8 test gear on a heavy-vehicle simulator. Flexible pavement rutting, rigid pavement cracking and spalling, instrumentation response, and falling-weight deflectometer data were monitored at select traffic intervals. The results of the trafficking tests indicated that existing design predictions were generally overconservative. Thus, minimum pavement layer thickness recommendations were made to support a minimum level of contingency operations. The results of full-scale flexible pavement experiment were utilized to support an analytical modeling effort to extend flexible pavement thickness recommendations beyond those evaluated.
  • Waste Management and Landfill Facilities Assessment Using Unmanned Aircraft Systems

    Abstract: Finite and decreasing landfill space on Army installations is a significant concern. Efficient waste management is essential for achieving resiliency and extending the lifespan of remaining landfills. The purpose of this demonstration was to conduct independent performance tests of small unmanned aircraft systems (sUAS) and their utility for providing landfill assessments in remote areas where physical presence is either dangerous or inefficient. An active, near capacity construction and demolition (C&D) landfill at Fort Gordon, Georgia, was identified for the demonstration. The flights, data requirements, and outputs generated by the sUAS flyovers were analyzed for efficacy in detecting cell capacity and subsidence. Each flight took 1–2 hours for mobilization, ground marker placement, flight, and postflight analysis. Volumetric and topographic surveys were analyzed in less time than is typical for traditional surveying methods. After initial setup of ground markers and rectification, sUAS flights save a significant amount of time. However, skilled individuals are required for flights and for processing and maintaining data. The technology is widely relevant to the Army, is commercially available, and offers an average of 30% cost savings in terms of manpower, repeatability, and equipment. The use of sUAS technology is recommended for monitoring and surveying Army landfills.
  • A Review of Airfield Pavement Drainage Guidance

    Abstract: Inadequate drainage conditions may lead to airfield pavement deterioration. A thorough review of existing pavement drainage guidance and literature was necessary to identify key drainage considerations such as surface drainage infrastructure, pavement drainage layer thickness, use of geotextiles, and performance in freeze–thaw climates. Existing airport drainage guidance is provided by the Unified Facilities Criteria (UFC), the Federal Aviation Administration (FAA), and the Tri-Service Pavements Working Group (TSPWG). Pavement drainage guidance is buried within regulations for pavement de-sign and can, at times, be split awkwardly to accommodate pavement guidance that is split between rigid and flexible designs. Most airfield pavement guidance has been adapted from guidance for highway design. Most guidance is also strength based, with little to no attention paid to material erodibility (a potential cause of pavement deterioration). This review also found very little reference to repairing, rather than completely replacing, damaged subsurface drainage layers. Further research is needed to assess the use of geofabrics and moisture in freeze–thaw conditions on drainage layers and surface structures. With further research, the retrofit and repair of existing subpavement systems might become a more economical solution to drainage-caused pavement deterioration issues than complete reconstruction.
  • Fort McCoy Firing Ranges and Military Training Lands: A History and Analysis

    Abstract: The US Congress codified the National Historic Preservation Act of 1966 (NHPA), the nation’s most effective cultural resources legislation to date, mostly through establishing the National Register of Historic Places (NRHP). The NHPA requires Federal agencies to address their cultural resources, which are defined as any prehistoric or historic district, site, building, structure, or object. Section 110of the NHPA requires Federal agencies to inventory and evaluate their cultural resources, and Section 106 requires them to determine the effect of Federal undertakings on those potentially eligible for the NRHP. Fort McCoy is entirely within Monroe County in west-central Wisconsin. It was first established as the Sparta Maneuver Tract in 1909.The post was renamed Camp McCoy in 1926. Since 1974, it has been known as Fort McCoy. This report provides a historic context for ranges, features, and buildings associated with the post’s training lands in support of Section 110 of the NHPA.
  • Evaluation of a Prototype Integrated Pavement Screed for Screeding Asphalt or Concrete Crater Repairs

    Abstract: Finishing, or screeding, the hot mix asphalt or rapid-setting concrete surface of a crater repair is important for rapid airfield damage recovery (RADR) since it determines the aircraft ride surface quality. The objective of RADR repairs is to expediently produce a flush repair, defined as ±0.75 in. of the surrounding pavement surface, with minimal logistical and personnel burden. Multiple screeds were previously evaluated; the most recent project proposed a prototype design of a telehandler-operated integrated screed for both small and large repairs using asphalt or concrete. This project’s objective was to finalize the prototype design and fabricate and test the prototype RADR screed. The prototype RADR screed was successful for small repairs (8.5×8.5 ft). Large repairs (30×30 ft) were generally successful with modest repair quality criteria (RQC) issues being the only notable deficiencies. Large concrete repair RQC issues were attributed to plastic formwork movement, and large asphalt repair RQC issues were attributed to compaction issues or improper roll-down factors. Methods to mitigate these factors were investigated but should be further evaluated. Overall, the RADR screed was successful from technical perspectives but, functionally, is 600-800 lb overweight. Weight reduction should be considered before entering production.
  • Standard Operating Procedures for Open-Air Solid Waste Burning in Contingency Locations

    Abstract: Service engineer doctrine and field manuals, such as Army Techniques Publication 3-34.40, Technical Manual 5-634, and Army Regulation 420-1, offer guidance on solid waste management but do not provide the level of detail and practical guidance for open-air burning of solid waste to reduce risk to the Warfighter. Studies have shown that there could be ill health effects to service members from exposure to toxins from open-air burning. Further practical guidance is necessary to ensure that if there are no other means available for solid waste disposal, the risks associated with open-air burning are minimized as much as possible during contingency operations. Commands have limited resources and reduced personnel available to study which open-air burning procedures are optimal based on readiness and mission requirements. Planning for efficiency and risk avoidance in open-air burning operations includes several facets (e.g., site planning, processing, and recordkeeping considerations). This special report provides operational guidance to minimize risk of open-air burning for the Warfighter and other joint service personnel, particularly when there is no other alternative to open-air burning, during initial phase operating a burn pit or for waste management planning to establish standard operating procedures.
  • Effects of Impure Water Sources on Early-Age Properties of Calcium Sulfoaluminate Cements for Rapid Airfield Damage Recovery

    Abstract: In austere environments with limited access to clean water, it is advantageous to use nonpotable water for construction (i.e., mixing water for concrete.) In rapid-response situations such as rapid airfield damage recovery (RADR), the use of calcium sulfoaluminate (CSA) cements is beneficial for expedient pavement repairs because of their rapid strength gain characteristics. However, the hydration products formed by CSA cements are substantially different from those formed by ordinary portland cement and might react differently to impurities that water sources may contain. A laboratory study component investigated the application of various salts and impure sources of mixing water with commercially available CSA cement-based products. A field component studied the application of naturally occurring impure water sources for RADR. Recommendations are made for implementation of impure mixing water for RADR using commercially available flowable fill and concrete products made with CSA cement.