  • VI Preferential Pathways of a Large Government Building

    Abstract: Trichloroethylene (TCE) releases from leaks and spills next to a large government building occurred over several decades with the most recent event occurring 20 years ago. In response to a perceived conventional vapor intrusion (VI) issue a sub-slab depressurization system (SSDS) was installed 6 years ago. The SSDS is operating within design limits and has achieved building TCE vapor concentration reductions. However, subsequent periodic TCE vapor spikes based on daily HAPSITE™ measurements indicate additional source(s). Two rounds of smoke tests conducted in 2017 and 2018 involved introduction of smoke into a sanitary sewer and storm drain manholes located on effluent lines coming from the building until smoke was observed exiting system vents on the roof. Smoke testing revealed many leaks in both the storm sewer and sanitary sewer systems within the building. Sleuthing of the VI source term using a portable HAPSITE™ indicate elevated vapor TCE levels correspond with observed smoke emanation from utility lines. Sleuthing activities also found building roof materials explain some of the elevated TCE levels on the 2nd floor. Installation of an external blower in the roof truss space has greatly reduced TCE levels. Preferential VI pathways and unexpected source terms may be overlooked mechanisms as compared to conventional VI.
  • VI Preferential Pathways: Rule or Exception

    Abstract: Trichloroethylene (TCE) releases from leaks and spills next to a large government building occurred over several decades with the most recent event occurring 20 years ago. In response to a perceived conventional vapor intrusion (VI) issue a sub-slab depressurization system (SSDS) was installed 6 years ago. The SSDS is operating within design limits and has achieved building TCE vapor concentration reductions. However, subsequent periodic TCE vapor spikes based on daily HAPSITE™ measurements indicate additional source(s). Two rounds of smoke tests conduct-ed in 2017 and 2018 involved introduction of smoke into a sanitary sewer and storm drain manholes located on effluent lines coming from the building until smoke was observed exiting system vents on the roof. Smoke testing revealed many leaks in both the storm sewer and sanitary sewer systems within the building. Sleuthing of the VI source term using a portable HAPSITE™ indicate elevated vapor TCE levels correspond with observed smoke emanation from utility lines. In some instances, smoke odors were perceived but no leak or suspect pipe was identified suggesting the odor originates from an unidentified pipe located behind or enclosed in a wall. Sleuthing activities also found building roof materials explain some of the elevated TCE levels on the 2nd floor. A relationship was found between TCE concentrations in the roof truss area, plenum space above 2nd floor offices, and breathing zone of 2nd floor offices. Installation of an external blower in the roof truss space has greatly reduced TCE levels in the plenum and office spaces. Preferential VI pathways and unexpected source terms may be overlooked mechanisms as compared to conventional VI.
  • Corps of Engineers partners with community as it expands environmental sampling beyond Hanover lab site

    HANOVER, NH – The U.S. Army Environmental Command and the U.S. Army Corps of Engineers are working with the New Hampshire Department of Environmental Services (NHDES), Dartmouth College, the Town of Hanover, and School Administrative Unit #70, public schools of Hanover, as they expand their continuing, on-site environmental monitoring program to